2026/10/31 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:01:255
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2026/10/30 0.5807 1.02031 0.9689 00.6237 00.0000 00.0000 95.7169 02.5282 00.1379 00.0074 00.0102 00.0000 00.0023 00.0017 00.0011 00.0008 00.0004 00.0000
CUSTER ST @ LINE AD ST1 2026/10/30 0.5797 1.01844 0.6184 01.1708 00.0000 00.0000 95.3859 02.7497 00.0720 00.0014 00.0015 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2026/10/30 0.5834 1.02443 0.8046 00.8767 00.0000 00.0000 94.9988 03.1442 00.1470 00.0076 00.0114 00.0000 00.0024 00.0017 00.0025 00.0018 00.0009 00.0000
CHANDLER ST DISCHARGE G 2026/10/30 0.5830 1.02393 0.7573 00.9374 00.0000 00.0000 94.9923 03.1609 00.1320 00.0065 00.0077 00.0000 00.0016 00.0012 00.0011 00.0008 00.0004 00.0000
FM 63 - Columbia GC @ 2 2026/10/30 0.6047 1.08081 0.2031 00.4190 00.0000 00.0000 90.3444 08.6606 00.3107 00.0213 00.0270 00.0000 00.0055 00.0035 00.0021 00.0015 00.0007 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.