MRT Gas Quality Daily Sample Report


 2023/05/23                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:437


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/05/22  0.5881   1.03276  0.7687   00.8716  00.0000   00.0000  94.1049    03.9968   00.2226    00.0098     00.0118     00.0000        00.0031      00.0022      00.0038    00.0028      00.0013     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/05/22  0.5828   1.01236  1.5762   00.3693  00.0000   00.0000  95.8262    02.1521   00.0690    00.0026     00.0035     00.0000        00.0000      00.0000      00.0003    00.0002      00.0001     00.0000
  SHATTUC - STREAM 1 @ 90     2023/05/22  0.6064   1.06400  1.0219   00.3796  00.0000   00.0000  90.8010    07.4092   00.3423    00.0197     00.0196     00.0000        00.0031      00.0014      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.