MRT Gas Quality Daily Sample Report


 2023/05/20                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:427


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/05/19  0.5873   1.03218  0.7874   00.8065  00.0000   00.0000  94.2838    03.8779   00.2036    00.0128     00.0126     00.0000        00.0037      00.0022      00.0043    00.0032      00.0015     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/05/19  0.5829   1.01309  1.4865   00.4720  00.0000   00.0000  95.7180    02.2304   00.0848    00.0031     00.0040     00.0000        00.0000      00.0000      00.0004    00.0003      00.0001     00.0000
  SHATTUC - STREAM 1 @ 90     2023/05/19  0.5851   1.01814  1.3912   00.5015  00.0000   00.0000  95.6151    02.1447   00.2134    00.0563     00.0342     00.0000        00.0160      00.0066      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.