MRT Gas Quality Daily Sample Report


 2023/05/18                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:565


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/05/17  0.5865   1.02889  0.8578   00.8200  00.0000   00.0000  94.5139    03.5722   00.1927    00.0137     00.0130     00.0000        00.0039      00.0024      00.0046    00.0034      00.0017     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/05/17  0.5813   1.00585  1.7964   00.2871  00.0000   00.0000  96.3073    01.5748   00.0318    00.0011     00.0013     00.0000        00.0000      00.0000      00.0000    00.0000      00.0000     00.0000
  SHATTUC - STREAM 1 @ 90     2023/05/17  0.5878   1.02659  1.1064   00.7105  00.0000   00.0000  94.6384    03.2310   00.2201    00.0388     00.0259     00.0000        00.0105      00.0041      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.