MRT Gas Quality Daily Sample Report


 2023/05/11                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:424


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/05/10  0.5855   1.02953  0.7853   00.7933  00.0000   00.0000  94.6480    03.5378   00.1950    00.0140     00.0138     00.0000        00.0037      00.0021      00.0031    00.0023      00.0011     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/05/10  0.5812   1.00959  1.6340   00.3023  00.0000   00.0000  96.2091    01.7800   00.0659    00.0036     00.0040     00.0000        00.0000      00.0000      00.0003    00.0002      00.0001     00.0000
  SHATTUC - STREAM 1 @ 90     2023/05/10  0.5877   1.02250  1.2928   00.6500  00.0000   00.0000  94.9273    02.7823   00.2290    00.0475     00.0332     00.0000        00.0140      00.0062      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.