MRT Gas Quality Daily Sample Report


 2023/05/01                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:02:032


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/30  0.5857   1.02797  0.8445   00.8155  00.0000   00.0000  94.6378    03.4829   00.1849    00.0110     00.0120     00.0000        00.0030      00.0019      00.0029    00.0021      00.0010     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/30  0.5841   1.02355  1.0252   00.6562  00.0000   00.0000  95.1050    03.0430   00.1451    00.0069     00.0094     00.0000        00.0020      00.0013      00.0025    00.0019      00.0009     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/30  0.5863   1.01955  1.3377   00.6221  00.0000   00.0000  95.2619    02.4431   00.2078    00.0527     00.0334     00.0000        00.0152      00.0062      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.