MRT Gas Quality Daily Sample Report


 2023/04/30                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:458


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/29  0.5856   1.02781  0.8521   00.8077  00.0000   00.0000  94.6529    03.4743   00.1788    00.0106     00.0121     00.0000        00.0030      00.0019      00.0029    00.0021      00.0010     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/29  0.5829   1.02027  1.1333   00.5796  00.0000   00.0000  95.4121    02.7333   00.1248    00.0059     00.0078     00.0000        00.0012      00.0000      00.0008    00.0005      00.0002     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/29  0.5867   1.01964  1.4214   00.5204  00.0000   00.0000  95.3156    02.3906   00.2140    00.0577     00.0359     00.0000        00.0168      00.0066      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.