MRT Gas Quality Daily Sample Report


 2023/04/26                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:312


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/25  0.5882   1.02985  0.8966   00.8653  00.0000   00.0000  94.1682    03.8419   00.1919    00.0103     00.0136     00.0000        00.0029      00.0024      00.0030    00.0022      00.0010     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/25  0.5854   1.02749  0.8859   00.7543  00.0000   00.0000  94.6954    03.4848   00.1551    00.0066     00.0091     00.0000        00.0016      00.0010      00.0027    00.0020      00.0009     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/25  0.5876   1.02082  1.4004   00.5729  00.0000   00.0000  95.0550    02.6489   00.2021    00.0515     00.0316     00.0000        00.0144      00.0057      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.