MRT Gas Quality Daily Sample Report


 2023/04/13                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:468


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/12  0.5816   1.02316  0.7048   00.9334  00.0000   00.0000  95.2693    02.9229   00.1350    00.0092     00.0123     00.0000        00.0030      00.0024      00.0034    00.0025      00.0012     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/12  0.5812   1.02084  0.8971   00.7410  00.0000   00.0000  95.4679    02.7926   00.0867    00.0046     00.0068     00.0000        00.0010      00.0000      00.0008    00.0006      00.0003     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/12  0.5862   1.02048  1.5195   00.2784  00.0000   00.0000  95.5269    02.3406   00.2037    00.0575     00.0338     00.0000        00.0154      00.0059      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.