MRT Gas Quality Daily Sample Report


 2023/04/11                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:538


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/10  0.5827   1.02415  0.7359   00.9277  00.0000   00.0000  95.0666    03.1076   00.1314    00.0085     00.0118     00.0000        00.0025      00.0018      00.0027    00.0020      00.0009     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/10  0.5806   1.02093  0.8738   00.7181  00.0000   00.0000  95.5729    02.7287   00.0892    00.0052     00.0073     00.0000        00.0014      00.0008      00.0010    00.0007      00.0003     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/10  0.5869   1.02124  1.5747   00.2100  00.0000   00.0000  95.5000    02.3475   00.2251    00.0629     00.0375     00.0000        00.0165      00.0064      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.