MRT Gas Quality Daily Sample Report


 2023/04/08                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:351


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/07  0.5800   1.02167  0.6349   00.9758  00.0000   00.0000  95.4975    02.7437   00.1181    00.0080     00.0108     00.0000        00.0027      00.0020      00.0028    00.0021      00.0010     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/07  0.5808   1.02118  0.8484   00.7580  00.0000   00.0000  95.5417    02.7246   00.1042    00.0058     00.0090     00.0000        00.0017      00.0012      00.0024    00.0018      00.0008     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/07  0.5867   1.02080  1.5770   00.2152  00.0000   00.0000  95.5228    02.3297   00.2158    00.0609     00.0361     00.0000        00.0165      00.0063      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.