MRT Gas Quality Daily Sample Report


 2023/04/07                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:424


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/06  0.5827   1.02426  0.7473   00.9032  00.0000   00.0000  95.1090    03.0592   00.1453    00.0097     00.0135     00.0000        00.0031      00.0023      00.0032    00.0024      00.0011     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/06  0.5821   1.02254  0.8918   00.7395  00.0000   00.0000  95.3072    02.9294   00.1113    00.0058     00.0082     00.0000        00.0015      00.0000      00.0023    00.0017      00.0008     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/06  0.5881   1.02288  1.5835   00.2130  00.0000   00.0000  95.2762    02.5434   00.2340    00.0660     00.0388     00.0000        00.0176      00.0067      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.