MRT Gas Quality Daily Sample Report


 2023/04/02                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:378


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/04/01  0.5829   1.02412  0.8164   00.8253  00.0000   00.0000  95.1712    02.9947   00.1489    00.0138     00.0145     00.0000        00.0040      00.0025      00.0038    00.0028      00.0013     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/04/01  0.5807   1.01702  1.0228   00.7311  00.0000   00.0000  95.6940    02.4587   00.0781    00.0039     00.0060     00.0000        00.0015      00.0008      00.0012    00.0009      00.0004     00.0000
  SHATTUC - STREAM 1 @ 90     2023/04/01  0.5877   1.01901  1.3360   00.8048  00.0000   00.0000  94.8201    02.7796   00.1721    00.0356     00.0245     00.0000        00.0100      00.0044      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.