MRT Gas Quality Daily Sample Report


 2023/04/01                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:339


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/30  0.5830   1.03101  0.8950   00.8005  00.0000   00.0000  95.2675    02.8123   00.1673    00.0183     00.0187     00.0000        00.0053      00.0035      00.0053    00.0039      00.0019     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/30  0.5810   1.03805  0.8048   00.8120  00.0000   00.0000  95.4710    02.7686   00.1174    00.0066     00.0093     00.0000        00.0020      00.0015      00.0029    00.0022      00.0010     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/30  0.5866   1.03158  1.2695   00.9477  00.0000   00.0000  95.0285    02.4447   00.2052    00.0442     00.0320     00.0000        00.0111      00.0050      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.