MRT Gas Quality Daily Sample Report


 2023/03/27                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:488


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/26  0.5864   1.02141  1.5192   00.2564  00.0000   00.0000  95.4694    02.4280   00.2036    00.0543     00.0308     00.0000        00.0130      00.0049      00.0094    00.0070      00.0034     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/26  0.5813   1.02077  0.8821   00.7848  00.0000   00.0000  95.4653    02.7260   00.1197    00.0065     00.0088     00.0000        00.0015      00.0000      00.0023    00.0017      00.0008     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/26  0.5863   1.01681  1.4086   00.6891  00.0000   00.0000  95.2319    02.3938   00.1764    00.0433     00.0269     00.0000        00.0114      00.0043      00.0067    00.0050      00.0024     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.