MRT Gas Quality Daily Sample Report


 2023/03/21                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:395


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/20  0.5886   1.02960  0.9270   00.8715  00.0000   00.0000  94.1450    03.8123   00.2006    00.0149     00.0140     00.0000        00.0037      00.0023      00.0038    00.0028      00.0014     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/20  0.5849   1.02416  1.0023   00.7356  00.0000   00.0000  94.8728    03.2349   00.1343    00.0050     00.0072     00.0000        00.0015      00.0000      00.0028    00.0020      00.0010     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/20  0.5874   1.01892  1.3641   00.7297  00.0000   00.0000  94.9916    02.6168   00.1940    00.0439     00.0274     00.0000        00.0123      00.0050      00.0070    00.0052      00.0025     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.