MRT Gas Quality Daily Sample Report


 2023/03/19                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:01:036


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/18  0.5868   1.02708  0.9475   00.8198  00.0000   00.0000  94.5618    03.4259   00.1929    00.0165     00.0167     00.0000        00.0049      00.0033      00.0049    00.0036      00.0017     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/18  0.5853   1.02680  0.8640   00.8272  00.0000   00.0000  94.6641    03.4637   00.1584    00.0057     00.0084     00.0000        00.0015      00.0011      00.0025    00.0019      00.0009     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/18  0.5879   1.02159  1.3484   00.6460  00.0000   00.0000  94.9555    02.7027   00.2215    00.0532     00.0336     00.0000        00.0151      00.0063      00.0081    00.0060      00.0029     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.