MRT Gas Quality Daily Sample Report


 2023/03/15                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:457


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/14  0.5874   1.02839  0.9468   00.7974  00.0000   00.0000  94.4395    03.5718   00.1939    00.0176     00.0159     00.0000        00.0046      00.0027      00.0044    00.0032      00.0016     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/14  0.5878   1.03068  0.8085   00.9064  00.0000   00.0000  94.1354    03.9390   00.1873    00.0059     00.0084     00.0000        00.0018      00.0011      00.0027    00.0020      00.0009     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/14  0.5880   1.02164  1.3576   00.6296  00.0000   00.0000  94.9753    02.6849   00.2236    00.0547     00.0343     00.0000        00.0154      00.0063      00.0084    00.0063      00.0030     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.