MRT Gas Quality Daily Sample Report


 2023/03/06                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:448


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/05  0.5865   1.02726  0.8822   00.8808  00.0000   00.0000  94.5003    03.5145   00.1837    00.0138     00.0120     00.0000        00.0034      00.0019      00.0032    00.0024      00.0011     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/05  0.5833   1.02521  0.8174   00.7968  00.0000   00.0000  95.0619    03.1401   00.1552    00.0087     00.0103     00.0000        00.0021      00.0011      00.0028    00.0021      00.0010     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/05  0.5880   1.02184  1.3871   00.5768  00.0000   00.0000  95.0402    02.6249   00.2309    00.0597     00.0369     00.0000        00.0165      00.0066      00.0094    00.0070      00.0034     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.