MRT Gas Quality Daily Sample Report


 2023/03/03                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:361


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2023/03/02  0.5862   1.02588  0.9250   00.8664  00.0000   00.0000  94.6239    03.3657   00.1740    00.0144     00.0145     00.0000        00.0043      00.0027      00.0041    00.0030      00.0014     00.0000
  MRT M/L @ MERAMEC_STR 3     2023/03/02  0.5810   1.01890  0.8592   00.9003  00.0000   00.0000  95.4752    02.6402   00.1016    00.0075     00.0096     00.0000        00.0023      00.0011      00.0012    00.0009      00.0004     00.0000
  SHATTUC - STREAM 1 @ 90     2023/03/02  0.5882   1.02232  1.3813   00.5761  00.0000   00.0000  95.0021    02.6624   00.2352    00.0612     00.0380     00.0000        00.0167      00.0068      00.0094    00.0070      00.0034     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.