MRT Gas Quality Daily Sample Report


 2022/05/24                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:352


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/23  0.5910   1.03886  0.7125   00.8707  00.0000   00.0000  93.4060    04.7838   00.1925    00.0098     00.0122     00.0000        00.0033      00.0024      00.0029    00.0022      00.0010     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/23  0.5807   1.00997  1.5362   00.3748  00.0000   00.0000  96.1990    01.8323   00.0506    00.0025     00.0033     00.0000        00.0000      00.0000      00.0004    00.0003      00.0001     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/23  0.6014   1.05412  1.1197   00.3143  00.0000   00.0000  91.8245    06.4280   00.2882    00.0113     00.0114     00.0000        00.0014      00.0000      00.0002    00.0002      00.0001     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.