MRT Gas Quality Daily Sample Report


 2022/05/20                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:398


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/19  0.5820   1.02649  0.6624   00.8398  00.0000   00.0000  95.1247    03.2218   00.1216    00.0082     00.0105     00.0000        00.0029      00.0022      00.0026    00.0019      00.0009     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/19  0.5842   1.01623  1.4674   00.4346  00.0000   00.0000  95.4500    02.5477   00.0905    00.0034     00.0047     00.0000        00.0000      00.0000      00.0005    00.0004      00.0002     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/19  0.5967   1.05486  0.8057   00.3058  00.0000   00.0000  92.4867    06.0906   00.2764    00.0158     00.0147     00.0000        00.0025      00.0000      00.0006    00.0004      00.0002     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.