MRT Gas Quality Daily Sample Report


 2022/05/19                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:364


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/18  0.5805   1.02467  0.6734   00.7888  00.0000   00.0000  95.4691    02.9142   00.1199    00.0090     00.0111     00.0000        00.0035      00.0026      00.0037    00.0027      00.0013     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/18  0.5841   1.01581  1.4853   00.4274  00.0000   00.0000  95.4785    02.5106   00.0886    00.0034     00.0046     00.0000        00.0000      00.0000      00.0005    00.0004      00.0002     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/18  0.5970   1.05533  0.8067   00.3048  00.0000   00.0000  92.4260    06.1522   00.2743    00.0158     00.0147     00.0000        00.0026      00.0010      00.0006    00.0004      00.0002     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.