 2022/05/14                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:297


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/13  0.5819   1.02678  0.6506   00.8283  00.0000   00.0000  95.1871    03.1552   00.1399    00.0102     00.0125     00.0000        00.0039      00.0029      00.0042    00.0031      00.0015     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/13  0.5835   1.01274  1.6137   00.3610  00.0000   00.0000  95.7192    02.2218   00.0750    00.0037     00.0044     00.0000        00.0000      00.0000      00.0003    00.0002      00.0001     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/13  0.6005   1.05572  1.0020   00.3159  00.0000   00.0000  91.8780    06.5006   00.2769    00.0124     00.0115     00.0000        00.0016      00.0000      00.0003    00.0002      00.0001     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.