MRT Gas Quality Daily Sample Report


 2022/05/12                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:374


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/11  0.5912   1.04006  0.7377   00.7775  00.0000   00.0000  93.4880    04.7093   00.2437    00.0117     00.0146     00.0000        00.0043      00.0032      00.0045    00.0033      00.0016     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/11  0.5811   1.01142  1.5483   00.3102  00.0000   00.0000  96.1705    01.8818   00.0766    00.0046     00.0054     00.0000        00.0011      00.0000      00.0005    00.0003      00.0001     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/11  0.5993   1.05862  0.8176   00.3076  00.0000   00.0000  91.9643    06.6002   00.2760    00.0159     00.0143     00.0000        00.0025      00.0000      00.0006    00.0004      00.0002     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.