MRT Gas Quality Daily Sample Report


 2022/05/09                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:327


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/08  0.5905   1.03936  0.7036   00.8032  00.0000   00.0000  93.5441    04.7042   00.2065    00.0110     00.0135     00.0000        00.0038      00.0028      00.0033    00.0025      00.0012     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/08  0.5823   1.01455  1.4468   00.3889  00.0000   00.0000  95.8184    02.2514   00.0831    00.0044     00.0054     00.0000        00.0000      00.0000      00.0006    00.0004      00.0002     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/08  0.6009   1.06148  0.8044   00.3079  00.0000   00.0000  91.6372    06.9265   00.2875    00.0169     00.0151     00.0000        00.0026      00.0000      00.0006    00.0004      00.0002     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.