MRT Gas Quality Daily Sample Report


 2022/05/07                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:399


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/06  0.5885   1.03493  0.7401   00.8246  00.0000   00.0000  93.9925    04.2000   00.1997    00.0120     00.0148     00.0000        00.0044      00.0032      00.0039    00.0029      00.0014     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/06  0.5849   1.02275  1.1960   00.5195  00.0000   00.0000  95.0731    03.0800   00.1144    00.0057     00.0076     00.0000        00.0016      00.0000      00.0007    00.0005      00.0002     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/06  0.6055   1.06002  1.1295   00.3300  00.0000   00.0000  91.0037    07.2178   00.2932    00.0122     00.0110     00.0000        00.0014      00.0000      00.0003    00.0002      00.0001     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.