MRT Gas Quality Daily Sample Report


 2022/05/06                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:352


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/05  0.5882   1.03600  0.7157   00.7739  00.0000   00.0000  94.1116    04.1422   00.1947    00.0118     00.0146     00.0000        00.0042      00.0031      00.0131    00.0098      00.0047     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/05  0.5856   1.02648  1.0784   00.5434  00.0000   00.0000  94.8221    03.4082   00.1297    00.0063     00.0083     00.0000        00.0016      00.0000      00.0008    00.0006      00.0003     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/05  0.6075   1.06408  1.0656   00.3712  00.0000   00.0000  90.5511    07.6732   00.3107    00.0130     00.0122     00.0000        00.0017      00.0000      00.0004    00.0003      00.0001     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.