MRT Gas Quality Daily Sample Report


 2022/05/03                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:389


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/05/02  0.5871   1.03473  0.7437   00.7040  00.0000   00.0000  94.2840    04.0441   00.1767    00.0124     00.0151     00.0000        00.0051      00.0038      00.0050    00.0037      00.0018     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/05/02  0.5857   1.02861  0.9783   00.5780  00.0000   00.0000  94.8514    03.3132   00.2394    00.0125     00.0195     00.0000        00.0024      00.0018      00.0013    00.0010      00.0004     00.0000
  SHATTUC - STREAM 1 @ 90     2022/05/02  0.6081   1.06400  1.1111   00.3663  00.0000   00.0000  90.4981    07.6607   00.3313    00.0148     00.0140     00.0000        00.0021      00.0000      00.0006    00.0004      00.0002     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.