MRT Gas Quality Daily Sample Report


 2022/04/26                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:377


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/04/25  0.5842   1.02829  0.8011   00.7224  00.0000   00.0000  94.9572    03.2887   00.1777    00.0153     00.0180     00.0000        00.0054      00.0037      00.0047    00.0035      00.0017     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/04/25  0.5854   1.03090  0.8465   00.6150  00.0000   00.0000  94.7092    03.6127   00.1809    00.0118     00.0152     00.0000        00.0030      00.0019      00.0015    00.0011      00.0005     00.0000
  SHATTUC - STREAM 1 @ 90     2022/04/25  0.6037   1.06001  0.9912   00.3747  00.0000   00.0000  91.2978    06.9688   00.3229    00.0185     00.0180     00.0000        00.0031      00.0015      00.0014    00.0010      00.0005     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.