MRT Gas Quality Daily Sample Report

 2022/04/15                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:359


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/04/14  0.5842   1.02829  0.8011   00.7224  00.0000   00.0000  94.9572    03.2887   00.1777    00.0153     00.0180     00.0000        00.0054      00.0037      00.0047    00.0035      00.0017     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/04/14  0.5841   1.02667  0.8917   00.6717  00.0000   00.0000  94.9717    03.2921   00.1444    00.0085     00.0122     00.0000        00.0025      00.0018      00.0014    00.0010      00.0005     00.0000
  SHATTUC - STREAM 1 @ 90     2022/04/14  0.5852   1.02954  0.6477   00.9740  00.0000   00.0000  94.5437    03.6123   00.1749    00.0125     00.0189     00.0000        00.0043      00.0036      00.0036    00.0026      00.0013     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.