MRT Gas Quality Daily Sample Report

 2022/04/13                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:438


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/04/12  0.5843   1.02934  0.7539   00.7423  00.0000   00.0000  94.8880    03.3799   00.1830    00.0158     00.0183     00.0000        00.0051      00.0036      00.0046    00.0034      00.0016     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/04/12  0.5863   1.02883  0.8886   00.7577  00.0000   00.0000  94.4964    03.6956   00.1338    00.0068     00.0102     00.0000        00.0022      00.0016      00.0031    00.0023      00.0011     00.0000
  SHATTUC - STREAM 1 @ 90     2022/04/12  0.5862   1.02666  1.1710   00.4470  00.0000   00.0000  94.8418    03.3670   00.1504    00.0066     00.0094     00.0000        00.0019      00.0015      00.0013    00.0010      00.0004     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.