MRT Gas Quality Daily Sample Report

 2022/04/05                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:373


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/04/04  0.5827   1.02700  0.7199   00.7873  00.0000   00.0000  95.1282    03.1529   00.1671    00.0136     00.0156     00.0000        00.0043      00.0031      00.0035    00.0026      00.0012     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/04/04  0.5837   1.02390  0.9428   00.7311  00.0000   00.0000  95.0600    03.1165   00.1230    00.0065     00.0102     00.0000        00.0020      00.0015      00.0028    00.0021      00.0010     00.0000
  SHATTUC - STREAM 1 @ 90     2022/04/04  0.5865   1.03230  0.7504   00.7820  00.0000   00.0000  94.6104    03.5236   00.2266    00.0305     00.0328     00.0000        00.0152      00.0071      00.0099    00.0074      00.0036     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.