MRT Gas Quality Daily Sample Report

 2022/03/26                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:402


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/03/25  0.5777   1.02026  0.6373   00.8405  00.0000   00.0000  96.0686    02.2566   00.1490    00.0124     00.0173     00.0000        00.0047      00.0038      00.0044    00.0033      00.0016     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/03/25  0.5757   1.01645  0.7150   00.7654  00.0000   00.0000  96.4774    01.9003   00.1104    00.0079     00.0120     00.0000        00.0026      00.0020      00.0031    00.0023      00.0011     00.0000
  SHATTUC - STREAM 1 @ 90     2022/03/25  0.5922   1.04890  0.6783   00.4282  00.0000   00.0000  93.5207    04.9438   00.3170    00.0406     00.0348     00.0000        00.0153      00.0049      00.0075    00.0056      00.0027     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.