MRT Gas Quality Daily Sample Report

 2022/03/15                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:296


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/03/14  0.5797   1.02274  0.6611   00.8504  00.0000   00.0000  95.6892    02.5995   00.1450    00.0131     00.0170     00.0000        00.0056      00.0047      00.0065    00.0048      00.0023     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/03/14  0.5788   1.01912  0.8348   00.7138  00.0000   00.0000  96.0073    02.2853   00.1198    00.0085     00.0139     00.0000        00.0033      00.0029      00.0047    00.0035      00.0017     00.0000
  SHATTUC - STREAM 1 @ 90     2022/03/14  0.5850   1.02410  0.8758   00.9358  00.0000   00.0000  94.8379    03.1314   00.1589    00.0128     00.0233     00.0000        00.0057      00.0054      00.0059    00.0044      00.0021     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.