MRT Gas Quality Daily Sample Report

 2022/03/14                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:307


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/03/13  0.5791   1.02242  0.6689   00.7994  00.0000   00.0000  95.8158    02.5190   00.1481    00.0123     00.0161     00.0000        00.0048      00.0040      00.0052    00.0039      00.0019     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/03/13  0.5790   1.01926  0.8263   00.7423  00.0000   00.0000  95.9507    02.3163   00.1240    00.0088     00.0140     00.0000        00.0034      00.0030      00.0050    00.0037      00.0018     00.0000
  SHATTUC - STREAM 1 @ 90     2022/03/13  0.5851   1.02351  0.9310   00.9014  00.0000   00.0000  94.8563    03.0972   00.1583    00.0117     00.0217     00.0000        00.0050      00.0043      00.0060    00.0044      00.0021     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.