MRT Gas Quality Daily Sample Report

 2022/03/13                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:01:085


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/03/12  0.5811   1.02472  0.7251   00.7594  00.0000   00.0000  95.5194    02.7688   00.1718    00.0141     00.0182     00.0000        00.0055      00.0045      00.0060    00.0045      00.0021     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/03/12  0.5798   1.02025  0.8402   00.7323  00.0000   00.0000  95.8089    02.4592   00.1200    00.0082     00.0136     00.0000        00.0032      00.0026      00.0053    00.0040      00.0019     00.0000
  SHATTUC - STREAM 1 @ 90     2022/03/12  0.5853   1.02463  0.9129   00.8771  00.0000   00.0000  94.8061    03.1924   00.1573    00.0112     00.0197     00.0000        00.0054      00.0048      00.0060    00.0044      00.0021     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.