MRT Gas Quality Daily Sample Report

 2022/03/11                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:303


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/03/10  0.5822   1.02727  0.7692   00.6481  00.0000   00.0000  95.3547    02.9982   00.1700    00.0152     00.0191     00.0000        00.0061      00.0048      00.0066    00.0049      00.0024     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/03/10  0.5780   1.01677  0.9125   00.6665  00.0000   00.0000  96.2092    02.0763   00.1022    00.0073     00.0119     00.0000        00.0028      00.0025      00.0039    00.0029      00.0014     00.0000
  SHATTUC - STREAM 1 @ 90     2022/03/10  0.5875   1.02652  1.0123   00.8179  00.0000   00.0000  94.5537    03.3633   00.1754    00.0154     00.0261     00.0000        00.0084      00.0074      00.0093    00.0069      00.0033     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.