MRT Gas Quality Daily Sample Report

 2022/03/07                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:375


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/03/06  0.5785   1.02086  0.7420   00.7234  00.0000   00.0000  96.0149    02.3358   00.1341    00.0130     00.0158     00.0000        00.0052      00.0040      00.0054    00.0040      00.0019     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/03/06  0.5796   1.02051  0.8502   00.6829  00.0000   00.0000  95.8438    02.4708   00.1186    00.0083     00.0122     00.0000        00.0025      00.0019      00.0039    00.0029      00.0014     00.0000
  SHATTUC - STREAM 1 @ 90     2022/03/06  0.5881   1.02908  1.0039   00.7395  00.0000   00.0000  94.4424    03.5246   00.2125    00.0231     00.0260     00.0000        00.0079      00.0047      00.0071    00.0053      00.0025     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.