MRT Gas Quality Daily Sample Report

 2022/03/01                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:349


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/02/28  0.5873   1.03694  0.6318   00.7611  00.0000   00.0000  94.1418    04.2281   00.1862    00.0123     00.0177     00.0000        00.0049      00.0043      00.0053    00.0040      00.0019     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/02/28  0.5841   1.02167  1.1514   00.5778  00.0000   00.0000  95.2525    02.8568   00.1259    00.0079     00.0124     00.0000        00.0031      00.0026      00.0042    00.0031      00.0015     00.0000
  SHATTUC - STREAM 1 @ 90     2022/02/28  0.5882   1.02899  1.0128   00.7392  00.0000   00.0000  94.4020    03.5755   00.2013    00.0198     00.0236     00.0000        00.0074      00.0047      00.0062    00.0046      00.0022     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.