MRT Gas Quality Daily Sample Report

 2022/02/23                         ENABLE MISSISSIPPI RIVER TRANSMISSION, LLC              PAGE:     1
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                             MVNX3020
                                                                                               TIME: 15:00:373


         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------

  MRT M/L @ PERRYVILLE  @     2022/02/22  0.5839   1.03240  0.6404   00.6951  00.0000   00.0000  94.8214    03.6358   00.1637    00.0123     00.0145     00.0000        00.0042      00.0031      00.0042    00.0031      00.0015     00.0000
  MRT M/L @ MERAMEC_STR 3     2022/02/22  0.5820   1.02016  1.0871   00.5747  00.0000   00.0000  95.5797    02.6132   00.1155    00.0066     00.0105     00.0000        00.0025      00.0021      00.0036    00.0027      00.0013     00.0000
  SHATTUC - STREAM 1 @ 90     2022/02/22  0.5897   1.03145  0.8548   00.9701  00.0000   00.0000  93.9581    03.9218   00.2156    00.0172     00.0299     00.0000        00.0082      00.0076      00.0077    00.0057      00.0027     00.0000



 The information displayed above reflects daily average gas quality readings
 taken at key locations on the MRT system.  The dates shown above are the
 dates of the readings.  The readings are taken daily, and information from such
 readings is posted on the first day thereafter.  If on any reading day there
 are problems retrieving the data, the last reported readings will remain
 posted until such time as new readings are obtained.  Due to factors such as
 equipment failure, sample contamination and human error, the information
 displayed above may not be completely accurate.