2023/11/24 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:194 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2023/11/23 0.5832 1.01969 1.3160 00.3650 00.0000 00.0000 95.6801 02.4077 00.1925 00.0133 00.0158 00.0000 00.0036 00.0022 00.0015 00.0011 00.0005 00.0000 CUSTER ST @ LINE AD ST1 2023/11/16 0.5691 1.00822 0.5672 00.8629 00.0000 00.0000 97.5213 01.0042 00.0411 00.0012 00.0018 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2023/11/23 0.5957 1.04536 0.7203 00.9147 00.0000 00.0000 92.4929 05.5676 00.2802 00.0076 00.0109 00.0000 00.0018 00.0013 00.0011 00.0008 00.0004 00.0000 CHANDLER ST DISCHARGE G 2023/11/23 0.5938 1.04381 0.6816 00.8828 00.0000 00.0000 92.8431 05.3024 00.2678 00.0078 00.0091 00.0000 00.0015 00.0012 00.0011 00.0008 00.0004 00.0000 FM 63 - Columbia GC @ 2 2023/10/24 0.6000 1.00000 0.0000 00.0000 00.0000 00.0000 89.0000 08.0000 03.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.