2023/11/05 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:235 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2023/11/04 0.5829 1.02747 0.9266 00.4609 00.0000 00.0000 95.3392 03.0422 00.1973 00.0117 00.0139 00.0000 00.0031 00.0019 00.0012 00.0009 00.0004 00.0000 CUSTER ST @ LINE AD ST1 2023/11/04 0.5666 1.00761 0.6572 00.5253 00.0000 00.0000 98.1558 00.6379 00.0214 00.0009 00.0012 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2023/11/04 0.5920 1.03943 0.7676 00.8455 00.0000 00.0000 93.2777 04.8550 00.2238 00.0091 00.0131 00.0000 00.0026 00.0018 00.0016 00.0011 00.0005 00.0000 CHANDLER ST DISCHARGE G 2023/11/04 0.5977 1.04795 0.7612 00.8775 00.0000 00.0000 92.0999 06.0015 00.2384 00.0074 00.0087 00.0000 00.0016 00.0012 00.0010 00.0007 00.0003 00.0000 FM 63 - Columbia GC @ 2 2023/10/24 0.6000 1.00000 0.0000 00.0000 00.0000 00.0000 89.0000 08.0000 03.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.