2023/05/02 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:247 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2023/05/01 0.5820 1.02084 1.1005 00.5093 00.0000 00.0000 95.6486 02.5433 00.1698 00.0101 00.0114 00.0000 00.0025 00.0015 00.0011 00.0008 00.0004 00.0000 CUSTER ST @ LINE AD ST1 2023/05/01 0.5703 1.00825 0.5440 01.0069 00.0000 00.0000 97.2365 01.1675 00.0428 00.0009 00.0011 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2023/05/01 0.5859 1.03039 0.7209 00.8771 00.0000 00.0000 94.4445 03.7463 00.1845 00.0078 00.0108 00.0000 00.0023 00.0016 00.0017 00.0013 00.0006 00.0000 CHANDLER ST DISCHARGE G 2023/05/01 0.5901 1.03715 0.6833 00.9259 00.0000 00.0000 93.5381 04.6272 00.2107 00.0022 00.0025 00.0000 00.0045 00.0033 00.0008 00.0006 00.0003 00.0000 FM 63 - Columbia GC @ 2 2023/05/01 0.6000 1.12145 0.0000 00.0000 00.0000 00.0000 89.0000 08.0000 03.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.