2023/04/17 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:176 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2023/04/16 0.5821 1.02343 0.9945 00.5192 00.0000 00.0000 95.5841 02.6681 00.1956 00.0129 00.0156 00.0000 00.0036 00.0023 00.0018 00.0013 00.0006 00.0000 CUSTER ST @ LINE AD ST1 2023/04/16 0.5679 1.00897 0.5521 00.7284 00.0000 00.0000 97.7631 00.9202 00.0334 00.0010 00.0014 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2023/04/12 0.5791 1.04344 0.6226 00.9038 00.0000 00.0000 95.6267 02.7279 00.0996 00.0056 00.0077 00.0000 00.0017 00.0012 00.0012 00.0009 00.0004 00.0000 CHANDLER ST DISCHARGE G 2023/04/16 0.5862 1.03246 0.6524 00.8868 00.0000 00.0000 94.2692 04.0078 00.1698 00.0020 00.0023 00.0000 00.0042 00.0031 00.0008 00.0006 00.0003 00.0000 FM 63 - Columbia GC @ 2 2023/04/16 0.6000 1.12145 0.0000 00.0000 00.0000 00.0000 89.0000 08.0000 03.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.