2023/04/02 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:164 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2023/04/01 0.5809 1.01900 1.1427 00.4463 00.0000 00.0000 95.9692 02.2258 00.1771 00.0133 00.0158 00.0000 00.0037 00.0021 00.0017 00.0012 00.0006 00.0000 CUSTER ST @ LINE AD ST1 2023/04/01 0.5668 1.00891 0.4495 00.7866 00.0000 00.0000 97.8825 00.8374 00.0403 00.0014 00.0020 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2023/04/01 0.5831 1.02663 0.6389 00.9631 00.0000 00.0000 94.8479 03.4100 00.1185 00.0061 00.0085 00.0000 00.0019 00.0014 00.0016 00.0012 00.0005 00.0000 CHANDLER ST DISCHARGE G 2023/04/01 0.5797 1.02283 0.6043 00.9313 00.0000 00.0000 95.4571 02.9001 00.0930 00.0019 00.0021 00.0000 00.0044 00.0033 00.0009 00.0006 00.0003 00.0000 FM 63 - Columbia GC @ 2 2023/04/01 0.6000 1.12145 0.0000 00.0000 00.0000 00.0000 89.0000 08.0000 03.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.