2022/05/09 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:119 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- MAGNOLIA CHECK GC @ 769 2022/05/08 0.5817 1.02702 0.7958 00.5761 00.0000 00.0000 95.4038 03.0164 00.1778 00.0099 00.0135 00.0000 00.0030 00.0022 00.0006 00.0004 00.0002 00.0000 BAY CHECK GC @ 170610 2022/05/08 0.5827 1.02374 1.0620 00.4612 00.0000 00.0000 95.5469 02.6780 00.2062 00.0157 00.0186 00.0000 00.0043 00.0029 00.0020 00.0010 00.0005 00.0000 CUSTER ST @ LINE AD ST1 2022/05/08 0.5725 1.00894 0.5848 01.1147 00.0000 00.0000 96.8425 01.3722 00.0819 00.0016 00.0020 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2022/05/08 0.5907 1.04043 0.6203 00.8831 00.0000 00.0000 93.3882 04.8670 00.2119 00.0086 00.0122 00.0000 00.0026 00.0019 00.0017 00.0013 00.0006 00.0000 CHANDLER ST DISCHARGE G 2022/05/08 0.5939 1.04404 0.6285 00.9597 00.0000 00.0000 92.7648 05.3615 00.2625 00.0030 00.0038 00.0000 00.0074 00.0054 00.0014 00.0010 00.0005 00.0000 COLUMBIA GULF FROM CP @ 2022/05/08 0.5851 1.01755 1.6542 00.1522 00.0000 00.0000 95.9142 01.9672 00.1949 00.0465 00.0224 00.0000 00.0107 00.0036 00.0159 00.0119 00.0057 00.0000 FM 63 - Columbia GC @ 2 2022/05/08 0.6050 1.07919 0.2533 00.4677 00.0000 00.0000 90.5118 08.2608 00.4099 00.0310 00.0390 00.0000 00.0098 00.0061 00.0048 00.0035 00.0017 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.