2022/05/06 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:125 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- MAGNOLIA CHECK GC @ 769 2022/05/05 0.5813 1.02660 0.7768 00.5894 00.0000 00.0000 95.4773 02.9491 00.1759 00.0098 00.0130 00.0000 00.0029 00.0022 00.0015 00.0011 00.0005 00.0000 BAY CHECK GC @ 170610 2022/05/05 0.5832 1.02588 1.0009 00.4737 00.0000 00.0000 95.3632 02.9246 00.1955 00.0143 00.0165 00.0000 00.0043 00.0026 00.0022 00.0011 00.0005 00.0000 CUSTER ST @ LINE AD ST1 2022/05/05 0.5748 1.01292 0.7166 00.8874 00.0000 00.0000 96.5417 01.7732 00.0770 00.0017 00.0020 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2022/05/05 0.5897 1.03983 0.5914 00.8716 00.0000 00.0000 93.5534 04.7559 00.1949 00.0091 00.0135 00.0000 00.0029 00.0021 00.0022 00.0016 00.0008 00.0000 CHANDLER ST DISCHARGE G 2022/05/05 0.5943 1.04625 0.5674 00.9591 00.0000 00.0000 92.5509 05.6982 00.2063 00.0024 00.0028 00.0000 00.0056 00.0043 00.0012 00.0009 00.0004 00.0000 COLUMBIA GULF FROM CP @ 2022/05/05 0.5846 1.01781 1.6279 00.1356 00.0000 00.0000 96.0013 01.9126 00.1986 00.0493 00.0253 00.0000 00.0097 00.0035 00.0169 00.0126 00.0061 00.0000 FM 63 - Columbia GC @ 2 2022/05/05 0.6050 1.07919 0.2533 00.4677 00.0000 00.0000 90.5118 08.2608 00.4099 00.0310 00.0390 00.0000 00.0098 00.0061 00.0048 00.0035 00.0017 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.