2025/10/23 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:01:096
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2025/10/22 0.5834 1.02331 0.9428 00.7297 00.0000 00.0000 95.1769 02.9536 00.1705 00.0085 00.0105 00.0000 00.0024 00.0016 00.0013 00.0010 00.0004 00.0000
CUSTER ST @ LINE AD ST1 2025/10/22 0.5744 1.01500 0.8340 00.5499 00.0000 00.0000 96.7711 01.7755 00.0656 00.0018 00.0017 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2025/10/22 0.5898 1.03051 0.9891 00.8329 00.0000 00.0000 94.0469 03.8114 00.2749 00.0123 00.0177 00.0000 00.0036 00.0026 00.0038 00.0028 00.0014 00.0000
CHANDLER ST DISCHARGE G 2025/10/22 0.5890 1.02777 1.0928 00.7701 00.0000 00.0000 94.2308 03.6486 00.2206 00.0119 00.0150 00.0000 00.0031 00.0023 00.0021 00.0015 00.0007 00.0000
FM 63 - Columbia GC @ 2 2025/10/22 0.6029 1.07844 0.1959 00.4070 00.0000 00.0000 90.7315 08.2694 00.3263 00.0238 00.0299 00.0000 00.0063 00.0038 00.0026 00.0019 00.0009 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.