2025/03/15 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:121 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2025/03/14 0.5806 1.02144 0.9457 00.5785 00.0000 00.0000 95.7531 02.5401 00.1547 00.0090 00.0112 00.0000 00.0029 00.0018 00.0012 00.0009 00.0004 00.0000 CUSTER ST @ LINE AD ST1 2025/03/14 0.5728 1.01589 0.4741 00.8918 00.0000 00.0000 96.6794 01.9014 00.0502 00.0012 00.0016 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2025/03/14 0.5910 1.02993 1.0496 00.8956 00.0000 00.0000 93.7273 04.0976 00.1948 00.0098 00.0152 00.0000 00.0031 00.0023 00.0019 00.0014 00.0007 00.0000 CHANDLER ST DISCHARGE G 2025/03/14 0.5912 1.03409 0.8668 00.9420 00.0000 00.0000 93.4393 04.5636 00.1677 00.0072 00.0078 00.0000 00.0017 00.0012 00.0011 00.0008 00.0004 00.0000 FM 63 - Columbia GC @ 2 2025/03/14 0.6107 1.05719 0.3855 02.1124 00.0000 00.0000 90.7989 05.1248 01.1903 00.0869 00.1110 00.0000 00.0776 00.0692 00.0203 00.0151 00.0073 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.